<DescriptionText><text>
Turns on or off the "Down" air solenoid for lowering the load/unload table.
Note that the "Up" air solenoid must be off before the table can be lowered.
When both the "Up" and "Down" solenoids are off, the table is idle and will move
freely up or down.
</text></DescriptionText>
<DescriptionText><text>
CAUTION:  Do not turn this on when the plate door is closed and the table is up,
or when the table is up and the "Up" solenoid is not on.  The table air
cylinder MUST be pressurized is the opposite direction you want to move it, or
else the table will slam into place.
</text></DescriptionText>
</Description>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Trendsetter_VLF</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Syntax>
<NumberedList>
<ListItem><Text>
act tbdn on|off
</Text></ListItem>
</NumberedList>
</Syntax>
<Notes>
<DescriptionText><text>
</text></DescriptionText>
</Notes>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../commands/act_tbup.xml</LinkAddress><LinkTitle>Command: act tbup</LinkTitle></Link></li>
<li><Link><LinkAddress>../commands/table.xml</LinkAddress><LinkTitle>Command: table</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:38:44 2008 PST
</Updated>
<Links>
</Links>
</Command>